range |
Actassi
|
|
---|---|---|
product or component type |
Copper cable
|
|
colour tint |
Blue
|
|
cable shielding type |
F/UTP
|
type of cable |
4 pair cables
|
|
---|---|---|
communication network category |
6A
|
|
minimum return loss |
20 dB 1 kHz
23 dB 4 kHz 24.5 dB 8 kHz 25 dB 10 kHz 25 dB 16 kHz 25 dB 20 kHz 24.3 dB 25 kHz 23.6 dB 31.25 kHz 21.5 dB 62.5 kHz 20.1 dB 100 kHz 18 dB 200 kHz 17.3 dB 250 kHz 16.8 dB 300 kHz 15.9 dB 400 kHz 15.2 dB 500 kHz |
|
attenuation |
Guaranteed: 2.1 dB @ 1 MHz per 100 m cable
Guaranteed: 3.8 dB @ 4 MHz per 100 m cable Guaranteed: 5.3 dB @ 8 MHz per 100 m cable Guaranteed: 5.9 dB @ 10 MHz per 100 m cable Guaranteed: 7.5 dB @ 16 MHz per 100 m cable Guaranteed: 8.4 dB @ 20 MHz per 100 m cable Guaranteed: 9.4 dB @ 25 MHz per 100 m cable Guaranteed: 10.5 dB @ 31.25 MHz per 100 m cable Guaranteed: 15 dB @ 62.5 MHz per 100 m cable Guaranteed: 9.1 dB @ 100 MHz per 100 m cable Guaranteed: 27.6 dB @ 200 MHz per 100 m cable Guaranteed: 31.1 dB @ 250 MHz per 100 m cable Guaranteed: 34.3 dB @ 300 MHz per 100 m cable Guaranteed: 40.1 dB @ 400 MHz per 100 m cable Guaranteed: 45.3 dB @ 500 MHz per 100 m cable |
|
power sum alien near-end crosstalk [PSANEXT] |
67 dB at 1 MHz
67 dB at 4 MHz 67 dB at 8 MHz 67 dB at 10 MHz 67 dB at 16 MHz 67 dB at 20 MHz 67 dB at 25 MHz 67 dB at 31.25 MHz 65.6 dB at 62.5 MHz 65.6 dB at 100 MHz 58 dB at 200 MHz 56.5 dB at 250 MHz 55.3 dB at 300 MHz 53.5 dB at 400 MHz 52 dB at 500 MHz |
|
power sum attenuation to alien crosstalk ratio far-end [PSAACRF] |
66.2 dB at 4 MHz
60.1 dB at 8 MHz 58.2 dB at 10 MHz 54.1 dB at 16 MHz 52.2 dB at 20 MHz 50.2 dB at 25 MHz 48.3 dB at 31.25 MHz 42.3 dB at 62.5 MHz 38.2 dB at 100 MHz 32.2 dB at 200 MHz 30.2 dB at 250 MHz 28.7 dB at 300 MHz 26.2 dB at 400 MHz 24.2 dB at 500 MHz |
|
near end crosstalk [NEXT] |
Guaranteed: 74.3 dB at 1 MHz
Guaranteed: 65.3 dB at 4 MHz Guaranteed: 60.8 dB at 8 MHz Guaranteed: 59.3 dB at 10 MHz Guaranteed: 56.2 dB at 16 MHz Guaranteed: 54.8 dB at 20 MHz Guaranteed: 53.3 dB at 25 MHz Guaranteed: 51.9 dB at 31.25 MHz Guaranteed: 47.4 dB at 62.5 MHz Guaranteed: 44.3 dB at 100 MHz Guaranteed: 39.8 dB at 200 MHz Guaranteed: 38.3 dB at 250 MHz Guaranteed: 37.1 dB at 300 MHz Guaranteed: 35.3 dB at 400 MHz Guaranteed: 33.8 dB at 500 MHz |
|
input impedance |
100 Ohm (+/- 15 %) at 1…100 MHz
100 Ohm (+/- 22 %) at 100…250 MHz |
|
maximum loop resistance |
72 Ohm
|
|
capacitance unbalance |
330 pF / 100 m
|
|
maximum resistance unbalance |
5 %
|
|
wire insulation material |
PE
|
|
conductor material |
Solid bare copper
|
|
AWG gauge |
AWG 23
|
|
cable outer diameter |
7.3 mm
|
|
cable length |
305 m
|
|
cable weight |
17 kg
|
ambient air temperature for operation |
75 °C
|
|
---|---|---|
flame retardance |
CM
|
|
standards |
ISO/IEC 11801 Ea
ANSI/TIA-568-C.2 |
Reviews